CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
Check if terminal in PCB
area is pushed to final
position.
If not, reinsert it to final
position.
Set multimeter to
resistance gear.
In PCB area, measure the
resistance of defrost temp.
sensor with a multimeter.
Take note of value.
Measure the temperature
of freezer air duct, near the
defrost temp. sensor.
Use measured temperature
to find the standard
resistance value in
Temperature-Resistance
Chart for Sensor.
DIAGNOSIS 1
PROCEDURE 1
Remove all shelves.
Remove basket.
Remove screw covers.
Unscrew.
Pull the buttom air duct
out.
Disconnect the wires for
thermostat.
Take bottom air duct
away.
CHECK AND TEST 2
Check if the terminal
is inserted into final
position.
IF NOT, RESINSERT IT.
Check if the terminal is
stuffed with foam.
IF SO, USE TWEEZERS TO SMASH IT AND
REMOVE.
Check if sensor is
attached in proper
position, as shown in
picture.
If not, correct it.
Check if wire of defrost
sensor is broken.
If yes, replace it with a
new one.
Step 5
Disconnect terminal of
defrost temp. sensor.
Measure resistance of
defrost temp. sensor
from terminal in freezer,
and take note of it.
Step 7
Measure the temperature of defrost temp. sensor.
Use measured
temperature to find the
standard resistance
value in Temperature-
Resistance Chart for
Sensor.
DIAGNOSIS 2
Put detector into one
end of wires in PCB area.
Put another detector into
end of wires behind air
duct.
DIAGNOSIS 3
Make sure the sealing
sponges are in good
condition.
When reinstalling the air
duct, fasten the wires to
avoid crushing with air
duct.
Check to see if there is
a wide gap between air
duct and cabinet. If there
is, reinstall air duct.