PROCEDURE 1
Internal wires for defrost
heater are covered by freezer
air duct. To check, you
need to disassemble the
freezer air duct.
Remove all shelves.
Remove basket.
Remove screw covers.
Unscrew.
Pull the buttom air duct
out.
Disconnect the wires for
thermostat.
Take bottom air duct
away.
CHECK AND TESTÂ 1
Check if wires of defrost heater are broken or not.
DIAGNOSIS 1
PROCEDURE 2
Disconnect terminal of heater.
Unscrew the two screws
with 6mm cross-head
screwdriver.
Cut off the fastening
strap.
Take out the holding
foam.
Loosen heater fastening
clips.
Lift evaporator with heater up 20mm. Bottom of evaporator must be higher than the edge of water trough.
Remove the heater.
Reverse steps above to
reinstall the heater and
pay attention to the key
points below
Do not damage the
wires of the heater while
installing the new heater.
CHECK AND TEST 2
Power on the appliance and perform a leakage test.
DIAGNOSIS 2
Make sure the sealing sponges are in good condition.
When reinstalling the air
duct, fasten the wires to
avoid crushing with air
duct.
Check to see if there is
a wide gap between air
duct and cabinet. If there
is, reinstall air duct.