PROCEDURE 1

Note

Internal wires for defrost
heater are covered by freezer
air duct. To check, you
need to disassemble the
freezer air duct.

Step 1

Remove all shelves.

Step 2

Remove basket.

Step 3

Remove screw covers.


Step 4

Unscrew.


Step 5

Pull the buttom air duct
out.


Step 6

Disconnect the wires for
thermostat.

Step 7

Take bottom air duct
away.

CHECK AND TEST  1

Step 1

Check if wires of defrost heater are broken or not.

DIAGNOSIS 1


PROCEDURE 2


Step 1

Disconnect terminal of heater.

Step 2

Unscrew the two screws
with 6mm cross-head
screwdriver.



Step 3

Cut off the fastening
strap.

Step 4

Take out the holding
foam.

Step 5

Loosen heater fastening
clips.

Step 6

Lift evaporator with heater up 20mm. Bottom of evaporator must be higher than the edge of water trough.

Step 7

Remove the heater.


Reverse steps above to
reinstall the heater and
pay attention to the key
points below

Tip 1

Do not damage the
wires of the heater while
installing the new heater.

CHECK AND TEST 2

Step 1

Power on the appliance and perform a leakage test.

DIAGNOSIS 2


PROCEDURE 3


Tip 1

Make sure the sealing sponges are in good condition.

Tip 2

When reinstalling the air
duct, fasten the wires to
avoid crushing with air
duct.

Tip 3

Check to see if there is
a wide gap between air
duct and cabinet. If there
is, reinstall air duct.