CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
Check if terminal in PCB
area is inserted to final
position.
If not, reinsert it to final
position.
Check if wire order for
LED is right or not in
PCB area.
Right picture shows the
correct condition.
Check if wire order
is correct, or if terminal
is filled with foam.
Use tweezers to pick
foam out and insert the
terminal into its position
again.
DIAGNOSIS 1
GENERAL PROCEDURES
FOR RECONNECTING
INTERNAL WIRES.
Cut wire off.
Peel off the sleeve
Check to ensure proper wire order and reconnect them.
Tin soldering.
Cover connecting point with electrical tape.
CHECK AND TEST 2
Power on the appliance,
open fridge door, check
if LED light is on or not.
After power on, open
freezer door and press
switch in to check if LED
is off.
DIAGNOSIS 2
PROCEDURE 1
LED LIGHT WITHOUT CONTROL BOARD
Prize off the cover with 2mm slotted driver.
Unscrew with 6mm cross
-head screwdriver.
Prize the base out.
1)Prize back part out.
3) Pull the base out.
Disconnect the terminals.
Remove LED
CHECK AND TEST 3
Provide DC12V to LED on
the top to check if it is on
or not.
DIAGNOSIS 3
CHECK AND TEST 4
Set multimeter to resistance gear.
Check wire connection from PCB area to LED
area.
DIAGNOSIS 4