CHECK AND TEST 1
Power off the appliance and open the door to let internal temp. warm up to ambient temperature.
Set thermostat to max-
1 and power on the
appliance.
DIAGNOSIS 1
CHECK AND TEST 2
Keep the appliance
running, and pay
attention to the stop and
startup of compressor.
Find out the bulb.
After first stopping and second startup of compressor, measure temperature near thermostat bulb.
DIAGNOSIS 1
CASE 1:
TEMP. SETTING KNOB ON TOP COVER
PROCEDURE 1
Remove screw cover.
Unscrew.
Push the top cover
forward.
Take off the top cover.
Disconnect the knob from thermostat.
Disconnect terminals for thermostat
Pull capillary out from the foam.
PROCEDURE 2
When inserting thermostat into the hole, please ensure the seal of the hole is good.
CASE 2:
TEMP. SETTING KNOB ON THE FOREHEAD OF CABINET
PROCEDURE 1
Unscrew.
Unscrew.
Disconnect terminals for thermostat.
PROCEDURE 2
If you can’t insert the connecting shaft with knob into final position, please remove the knob first, then install the shaft into final position, and at last, install the knob.
Make sure the blue mark is outside the cabinet.
CASE 3:
TEMP. SETTING KNOB ON COMPRESSOR NICHE
PROCEDURE 1
Unscrew.
Prize up the thermostat knob.
PROCEDURE 2
Don’t forget to put the wires in right position and attach with a cable tie.
CHECK AND TEST 3
Performance Testing Procedures and Assessment Criteria.
1. Sensor position: Freezer: geometric center of freezer compartment.
2. Test time: 30min to 60min.
3. Stop Gear: compressor-stopping gear must be above the gear listed on the table.
4. Temperature drop must be no less than the value on the table.
DIAGNOSIS 3