PROCEDURE 1
Unscrew the locking plastic.
Remove the blue plastic.
Pull out integrated protector and starter.
CHECK AND TEST 1
Measure resistance between terminals for compressor on starter.
DIAGNOSIS 1
CHECK AND TEST 2
Measure resistance
between terminals for
compressor on protector.Measure resistance
between terminals for
compressor on protector.
DIAGNOSIS 1
PROCEDURE 2
CHECK AND TEST 1
Watch the warning light flashing on the mainboard.
Note: one flash is when the light goes on for 0.5 second and then off for 0.5 second.
PROCEDURE 1
Disconnect power cord.
PROCEDURE 2
PROCEDURE 3
Use a pair of pliers to cut off the charging tube.
Cut off exhaust pipe and suction pipe.
To get more details on brazing requirements, please go to page 366
Cut off capillary and remove the cut end by shaking.
Peform leakage test on brazed joints of drying- filter and compressor processing pipe.
Vacuum and recharge.
Please get more details of vacuuming and gas- charging requirements on page 313
Braze the ends and remove the pliers.
CHECK AND TEST 2
Performance Testing Procedures and Assessment Criteria.
1. Sensor position: Freezer: geometric center of freezer compartment.
2. Test time: 30min to 60min.
3. Stop Gear: compressor-stopping gear must be above the gear listed on the table.
4. Temperature drop must be no less than the value on the table.
DIAGNOSIS 1