CHECK AND TEST 1
Discharge refrigerant:
Cut off the charging tube
with pliers.
Discharge all refrigerant toward the exhaust vent
Melt brazing material with flame and pull out processing tube using a pair of pliers.
Re-braze a copper tube onto compressor processing tube. Click below link to get more details for brazing requirements, go to Annex B1
DIAGNOSIS 1
PROCEDURE 2
Step 1
Clean paint off of brazed
joint of drying filter.
Step 2
Cut off drying-filter.
Step 3
Cut off capillary and
shake to remove the cut
end.
Braze on a new dryingfilter.
Add quick connector onto processing pipe of drying-filter.
Step 7
Perform leakage test on
brazed joints of dryingfilter
and processing pipe
on compressor.
Block processing pipe twice by locking pliers.
CHECK AND TEST 2