CHECK AND TEST 1

Step 1

Plug off the product
and open the door to
let internal temperature
warm up to ambient
temperature.
If LED is off, it means the
appliance is switched off.

Step 2

Set the knob of
thermostat at gear
max-1, and plug in to
switch on the appliance.


DIAGNOSIS 1


CHECK AND TEST 2

Step 1

After first stop, please
consult below table to find
out bulb position, then
measure temperature
in the area near the
thermostat bulb.

DIAGNOSIS 2

PROCEDURE 1


Step 1

Lever off the screw
cover.

Step 2

Unscrew.

Step 3

Remove thermostat
cover.

Step 4

Pull capillary from the
hole.

Step 5

Disconnect terminal for
LED.

Step 6

Disconnect terminal for
thermostat.

Step 7

Lever off the knob.

Step 8

Unscrew the nut.

Step 9

Remove the thermostat.

PROCEDURE 2

Tip 1:

When inserting capillary
into the hole, make sure
the first red mark goes
into the hole, but second
one remains outside of
the hole.

Tip 2:

Make sure the pins of
thermostat cover are
inserted into the holes.

Tip 3:

Make sure wires are
placed into cavity of
thermostat.

CHECK AND TEST 3


Step 1

Set the knob of
thermostat at gear
max-1, and plug in to
switch on the appliance.

Step 2

After first stop, please
consult below table to find
out bulb position, then
measure temperature
in the area near the
thermostat bulb.

DIAGNOSIS 3

Step 1

testo testo

CHECK AND TEST 4


DIAGNOSIS 4