CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
Heat freezer temp. sensor.
Use multimeter to test the voltage of output for “BCK” & “GND”.
Take note of test result.
DIAGNOSIS 1
CHECK AND TEST 2
Press the button SW1
on mainboard, within 1
minute after powering on
the appliance, to start
manual defrost.
Test voltage of terminals
for defrost heater.
Step 3
Take note of the result. Later power off to quit manual defrost.
The value should be 230V or 115V.
DIAGNOSIS 2
PROCEDURE 1
Unscrew the mainboard..
Pull out the buckle to
take out wires.
Disconnect terminals.
Pull out the buckle to
remove mainboard.
PROCEDURE 2
DIAGNOSIS 3