CHECK AND TEST 1
Open freezer door to check if temperature controller is set to warmest position.
DIAGNOSIS 1
PROCEDURE 1
Remove freezer shelf.
Step 3
Unscrew 2 screws.
a. Hold the decorative cover of air duct;
b. Pull air duct out;
c. Disconnect the terminal of fan motor;
d. Remove freezer air duct.
Loosen the screw.
Lever clasps off.
Take away the foam.
Use knife to cut off 4mm
of wind shield at the 2
ends and top part (as
shown in photo).
Picture on right show the effect after cutting off.
DIAGNOSIS 1
Ensure proper alignment between foam and plastic.
Check the sealing of air duct.
If sponge is not compressed, we can assert there is a sealing problem.
Add a sponge to uncompressed area