CHECK AND TEST 1

Step 1

Unscrew cover of mainboard with a Cross-head screwdriver. 

Step 2

Press the button SW1 on mainboard, within 1 minute after powering on the appliance, to start manual defrost. 

Step 3

Test voltage of terminals for defrost heater.

WARNING:

please keep all terminals connected with mainboard, otherwise, mainboard cannot output power for heater. 

Step 4

Take note of the result. Later power off to quit manual defrost.

The value should be 230V or 115V. 

DIAGNOSIS 1


PROCEDURE 1


Step 1

Unscrew cover of mainboard with a Cross-head screwdriver. 

Step 2

Pull out the buckle to take out wires. 

Step 3

Unscrew the mainboard. 

Step 4

Disconnect terminals. 

Step 5

Pull out the buckle to remove mainboard.

Reverse above steps to install a new board. 

DIAGNOSIS 2