CHECK AND TEST 1
Step 3
Turn the knob from 0 to max to test resistance of potentiometer.
DIAGNOSIS 1
PROCEDURE 1
Remove chill box.
Lever 2 decorative strips off and remove.
Pull out fridge air duct.
PROCEDURE 2
Lever clasp off.
Reverse procedures above to reinstall potentiometer.
CHECK AND TEST 2
If not, repeat.
Step 3
If so, use tweezers to remove the foam.
Step 5
Check the connections of wires for potentiometer.
DIAGNOSIS 2
CHECK AND TEST 3
DIAGNOSIS 3
PROCEDURE 3
Reverse above steps to install a new board.
When reinstalling fridge air duct, first put the positive end of buckle on the top into the negative ends.
Then put the positive end of buckle on the sides into the negative ends.
Lastly, fasten the buckles on the sides by knocking them in.