CHECK AND TEST 1

Step 1

Open freezer door to check if temperature controller is set to coldest position. 

DIAGNOSIS 1





PROCEDURE 1

Step 1

Remove freezer shelf. 

Step 2

Lever 2 screw covers off. 

Step 3

Unscrew 2 screws. 

Step 4

Remove air duct:

a. Hold the decorative cover of air duct;

b. Pull air duct out; 

c. Disconnect the terminal of fan motor; 

d. Remove freezer air duct. 


Step 5

Loosen the screw. 

Step 6

Remove fan cover. 

Step 7

Lever clasps off. 

Step 8

Take away the foam. 

Step 9

Pull controller out of air duct plastic cover. 

Step 10

Use knife to cut off 4mm of wind shield at the 2 ends and top part showed on right picture. 

Step 11

picture in right side is the effect after cutting off. 

DIAGNOSIS 2

PROCEDURE 2

Tip 1

Make sure outlet for fridge is well-sealed. 

Tip 2

Ensure proper alignment between foam and plastic. 

Tip 3

Check the sealing of air duct. 

Tip 4

If sponge is not compressed, we can assert there is a sealing problem.  

Tip 5

Add a sponge to uncompressed area