CHECK AND TEST 1
Open freezer door to check if temperature controller is set to coldest position.
DIAGNOSIS 1
PROCEDURE 1
Remove freezer shelf.
Lever 2 screw covers off.
Step 3
Unscrew 2 screws.
Remove air duct:
a. Hold the decorative cover of air duct;
b. Pull air duct out;
c. Disconnect the terminal of fan motor;
Loosen the screw.
Remove fan cover.
Take away the foam.
Pull controller out of air duct plastic cover.
Use knife to cut off 4mm of wind shield at the 2 ends and top part showed on right picture.
picture in right side is the effect after cutting off.
DIAGNOSIS 2
Make sure outlet for fridge
is well-sealed.
Ensure proper alignment
between foam and plastic.
Check the sealing of air
duct.
If sponge is not compressed, we can assert there is a sealing problem.
Add a sponge to uncompressed area