CHECK AND TEST 1
Unscrew cover of mainboard with a cross-head screwdriver.
In PCB area, check if terminal is pushed into final position.
If not, redo it.
Remove foam with tweezers.
Measure resistance of heater from terminal in PCB area.
Check the result.
DIAGNOSIS 1
PROCEDURE 1
Remove freezer shelf.
Lever 2 screw covers off.
Step 3
Unscrew 2 screws.
Remove air duct:
a. Hold the decorative cover of air duct;
b. Pull air duct out;
c. Disconnect the terminal of fan motor;
d. Take air duct away.
CHECK AND TEST 2
Check if terminal is pushed into final
position.
If not, please re-insert the
terminal into the buckle.
Check if the terminal is filled with foam.
Step 3
Remove foam with tweezers.
DIAGNOSIS 2
PROCEDURE 2
Disconnect the terminal of heater.
Take out heat- conducting rod with slotted screw driver.
Lift evaporator and heater 20mm, the bottom must be higher than the edge of the trough.
WARNING:
Be careful not to deform pipes in red square during steps 4 & 5.
Loosen the clips for fastening heater. There are 8 clips in total.
Remove the heater.
Reverse procedures above to reinstall the heater.
CHECK AND TEST 3
Please press the button SW1 on mainboard (within 1 minute of powering on the appliance) to start manual defrost.
DIAGNOSIS 3
CHECK AND TEST 4
Connect 2 ends on terminal in PCB area.
Step 2
Check the connection of wires in foam.
DIAGNOSIS 4
When reinstalling air duct, move wires out of the way to prevent crushing by air duct.
After pushing air duct back into position, you should hear a clicking sound. If there is no click, please repeat again.
Check to see if there is a wide gap between air duct and cabinet.
If gap is large, re-install air duct.