CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
In PCB, check to see if terminal is filled with foam.
Step 4
If so, use tweezers to
remove it.
Take note of the result.
Measure the temperature of freezer air duct, close to sensor.
DIAGNOSIS 1
PROCEDURE 1
Remove freezer shelf.
Lever 2 screw covers off.
Step 3
Unscrew 2 screws.
Remove air duct:
a. Hold the decorative cover of air duct;
b. Pull air duct out;
c. Disconnect the terminal of fan motor;
d. Remove freezer air duct.
DIAGNOSIS 2
PROCEDURE 2
Cut wire off from broken area.
Peel off the sleeves.
Step 3
Check to ensure proper wire order and connect them.
Tin soldering.
Step 5
Cover connection with
electrical tape.
CHECK AND TEST 2
Use a multimeter to measure the resistance value of defrosting temp. sensor from terminal located in freezer.
Measure the temperature of sensor.
DIAGNOSIS 3
CHECK AND TEST 3
Check to see if the terminal is filled with foam.
If so, use tweezers to crush and remove foam.
Step 3
Make sure sensor is
properly located by
comparing with photo on
right.
If sensor is not in same position as photo, fix it.
Connect the 2 ends in PCB area.
DIAGNOSIS 4
When reinstalling air duct, move wires out of the way to prevent crushing by air duct.
Check to see if there is a wide gap between air duct and cabinet.
If gap is large, re-install air duct.