CHECK AND TEST 1
Unscrew cover of mainboard with a Cross-head screwdriver.
Step 3
In PCB, check to see if terminal is filled with foam.
Step 4
If so, use tweezers to remove it.
Take note of the result.
Measure the temperature of freezer air duct, close to sensor.
DIAGNOSIS 1
PROCEDURE 1
Remove freezer shelf.
Step 3
Unscrew 2 screws.
a. Hold the decorative cover of air duct;
b. Pull air duct out;
c. Disconnect the terminal of fan motor;
d. Remove freezer air duct.
CHECK AND TEST 2
DIAGNOSIS 2
PROCEDURE 2
Peel off the sleeves.
Step 3
Check to ensure proper wire order and connect them.
Step 5
Cover connection with electrical tape.
CHECK AND TEST 3
Insert the detectors into terminal and measure the resistance of sensor.
Take note of the result.
Measure the temperature of sensor.
DIAGNOSIS 3
CHECK AND TEST 4
Check to see if the terminal is filled with foam.
Step 2
If so, use a tweezers to remove it.
If sensor is not in same position as photo, follow the indication of picture to fix it.
DIAGNOSIS 4
PROCEDURE 3
Unscrew the mainboard.
Disconnect terminals.
Reverse above steps to install a new board.
When reinstalling air duct, move wires out of the way to prevent crushing by air duct.
If gap is large, re-install air duct.