8.5 RELIABILITY FAULTS:
DOOR STOPPER IS BROKEN
CHECK AND TEST 1
Open door to an angle
of 8° from cabinet.
If the door does not
close automatically, there
is a problem with the
door stopper.
Check the alignment between door stopper and hinge to find out root causes.
Check to see whether screw is screwed correctly into final position. If not this would cause misalignment between door stopper and hinge.
Check if there are too many washers, causing Misalignment between door stopper and hinge.
Check if the door stopper is deformed and causing misalignment.
DIAGNOSIS 1
PROCEDURE 1
Unscrew hinge cover.
Remove the cover.
Disconnect the terminals.
Unscrew 2 bolts and remove the top hinge.
Remove upper door.
Loosen the middle hinge and remove it.
Remove freezer door and replace with new one. Reverse above steps to install the new door.
Tilt cabinet.
Unscrew the adjustable foot.
Unscrew 4 bolts and remove bottom hinge.
Reverse procedures above to restore hinges and doors, however, please pay attention to the following tips:
Don’t forget to add washer onto hinge pin.
When installling door onto hinge, please check the match between door- stopper and hinge.
When installling door onto hinge, please check the match between door- stopper and hinge.
Tip 4
Make sure gaps between
doors are even.
DIAGNOSIS 2