Step 1 Check thermostat gear. If gear is set close to Max (such as to 6 or 7) and compressor is always running, turn knob slowly to warmer gear until the compressor stops.
DIAGNOSIS 1
DIAGNOSIS 2
CHECK AND TEST 2
Step 1
Set thermostat control knob to gear Min, and switch on the appliance.
Step 2
Perform following 2 tests: 1 When compressor stops for second time, measure temp in the area near the thermostat bulb. 2 When the compressor starts again, measure temp. in the area near the thermostat bulb.
DIAGNOSIS 3
PROCEDURE 1
Step 1
Lever off the screw cover.
Step 2 Unscrew.
Step 3
Remove thermostat cover.
Step 4 Pull capillary from the hole.
Step 5
Lever off the knob.
Step 7
Disconnect terminal for thermostat.
PROCEDURE 2
Tip 1:
When inserting capillary into the hole, make sure the first red mark goes in the hole, but second one remains outside of the hole.
Tip 2:
Make sure pins of thermostat cover are properly inserted into the holes.
Tip 3: Make sure wires are pushed into cavity for thermostat.
CHECK AND TEST 3
Step 1
Set the knob of thermostat at gear MIN, and plug in to switch on the appliance.
Step 2 After first stop, please consult table 1 to find bulb position, then measure temperature in the area near thermostat bulb.