CHECK AND TEST 1

Step 1

Plug off the product.
If LED is off, the
appliance is switched off.

PROCEDURE 1

Step 1

Remove LED cover.

Step 2
Unscrew

Step 3

Remove thermostat
cover.


Step 4

Pull capillary from the
hole.

Step 5

Lever off the knob.


Step 6
Disconnect terminal for
thermostat.

Step 7

Remove thermostat

Step 8

Test thermostat
individually

DIAGNOSIS 1

PROCEDURE 2


Tip 1:

When inserting capillary
into the hole, make sure
the first red mark goes in
the hole, but second one
remains outside of the
hole.

Tip 2:

Make sure pins of
thermostat cover are
properly inserted into the
holes.

Tip: 3

Make sure wires are
pushed into cavity for
thermostat.

DIAGNOSIS 2



Step 1

Set the knob of thermostat
to gear Max-1, and switch
on the appliance to do a
performance check.

Step 2
After 40min or 60 min,
test the internal temp.